# SPDX-License-Identifier: GPL-2.0-only
config NET_DSA_SJA1105
tristate "NXP SJA1105 Ethernet switch family support"
depends on NET_DSA && SPI
select NET_DSA_TAG_SJA1105
select PACKING
select CRC32
help
This is the driver for the NXP SJA1105 automotive Ethernet switch
family. These are 5-port devices and are managed over an SPI
interface. Probing is handled based on OF bindings and so is the
linkage to PHYLINK. The driver supports the following revisions:
- SJA1105E (Gen. 1, No TT-Ethernet)
- SJA1105T (Gen. 1, TT-Ethernet)
- SJA1105P (Gen. 2, No SGMII, No TT-Ethernet)
- SJA1105Q (Gen. 2, No SGMII, TT-Ethernet)
- SJA1105R (Gen. 2, SGMII, No TT-Ethernet)
- SJA1105S (Gen. 2, SGMII, TT-Ethernet)
net: dsa: sja1105: Add support for the PTP clock The design of this PHC driver is influenced by the switch's behavior w.r.t. timestamping. It exposes two PTP counters, one free-running (PTPTSCLK) and the other offset- and frequency-corrected in hardware through PTPCLKVAL, PTPCLKADD and PTPCLKRATE. The MACs can sample either of these for frame timestamps. However, the user manual warns that taking timestamps based on the corrected clock is less than useful, as the switch can deliver corrupted timestamps in a variety of circumstances. Therefore, this PHC uses the free-running PTPTSCLK together with a timecounter/cyclecounter structure that translates it into a software time domain. Thus, the settime/adjtime and adjfine callbacks are hardware no-ops. The timestamps (introduced in a further patch) will also be translated to the correct time domain before being handed over to the userspace PTP stack. The introduction of a second set of PHC operations that operate on the hardware PTPCLKVAL/PTPCLKADD/PTPCLKRATE in the future is somewhat unavoidable, as the TTEthernet core uses the corrected PTP time domain. However, the free-running counter + timecounter structure combination will suffice for now, as the resulting timestamps yield a sub-50 ns synchronization offset in steady state using linuxptp. For this patch, in absence of frame timestamping, the operations of the switch PHC were tested by syncing it to the system time as a local slave clock with: phc2sys -s CLOCK_REALTIME -c swp2 -O 0 -m -S 0.01 Signed-off-by: Vladimir Oltean <olteanv@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2019-06-08 06:04:34 -06:00
config NET_DSA_SJA1105_PTP
net: dsa: sja1105: fix ptp link error Due to a reversed dependency, it is possible to build the lower ptp driver as a loadable module and the actual driver using it as built-in, causing a link error: drivers/net/dsa/sja1105/sja1105_spi.o: In function `sja1105_static_config_upload': sja1105_spi.c:(.text+0x6f0): undefined reference to `sja1105_ptp_reset' drivers/net/dsa/sja1105/sja1105_spi.o:(.data+0x2d4): undefined reference to `sja1105et_ptp_cmd' drivers/net/dsa/sja1105/sja1105_spi.o:(.data+0x604): undefined reference to `sja1105pqrs_ptp_cmd' drivers/net/dsa/sja1105/sja1105_main.o: In function `sja1105_remove': sja1105_main.c:(.text+0x8d4): undefined reference to `sja1105_ptp_clock_unregister' drivers/net/dsa/sja1105/sja1105_main.o: In function `sja1105_rxtstamp_work': sja1105_main.c:(.text+0x964): undefined reference to `sja1105_tstamp_reconstruct' drivers/net/dsa/sja1105/sja1105_main.o: In function `sja1105_setup': sja1105_main.c:(.text+0xb7c): undefined reference to `sja1105_ptp_clock_register' drivers/net/dsa/sja1105/sja1105_main.o: In function `sja1105_port_deferred_xmit': sja1105_main.c:(.text+0x1fa0): undefined reference to `sja1105_ptpegr_ts_poll' sja1105_main.c:(.text+0x1fc4): undefined reference to `sja1105_tstamp_reconstruct' drivers/net/dsa/sja1105/sja1105_main.o:(.rodata+0x5b0): undefined reference to `sja1105_get_ts_info' Change the Makefile logic to always build the ptp module the same way as the rest. Another option would be to just add it to the same module and remove the exports, but I don't know if there was a good reason to keep them separate. Fixes: bb77f36ac21d ("net: dsa: sja1105: Add support for the PTP clock") Signed-off-by: Arnd Bergmann <arnd@arndb.de> Signed-off-by: David S. Miller <davem@davemloft.net>
2019-06-17 07:14:10 -06:00
bool "Support for the PTP clock on the NXP SJA1105 Ethernet switch"
net: dsa: sja1105: Add support for the PTP clock The design of this PHC driver is influenced by the switch's behavior w.r.t. timestamping. It exposes two PTP counters, one free-running (PTPTSCLK) and the other offset- and frequency-corrected in hardware through PTPCLKVAL, PTPCLKADD and PTPCLKRATE. The MACs can sample either of these for frame timestamps. However, the user manual warns that taking timestamps based on the corrected clock is less than useful, as the switch can deliver corrupted timestamps in a variety of circumstances. Therefore, this PHC uses the free-running PTPTSCLK together with a timecounter/cyclecounter structure that translates it into a software time domain. Thus, the settime/adjtime and adjfine callbacks are hardware no-ops. The timestamps (introduced in a further patch) will also be translated to the correct time domain before being handed over to the userspace PTP stack. The introduction of a second set of PHC operations that operate on the hardware PTPCLKVAL/PTPCLKADD/PTPCLKRATE in the future is somewhat unavoidable, as the TTEthernet core uses the corrected PTP time domain. However, the free-running counter + timecounter structure combination will suffice for now, as the resulting timestamps yield a sub-50 ns synchronization offset in steady state using linuxptp. For this patch, in absence of frame timestamping, the operations of the switch PHC were tested by syncing it to the system time as a local slave clock with: phc2sys -s CLOCK_REALTIME -c swp2 -O 0 -m -S 0.01 Signed-off-by: Vladimir Oltean <olteanv@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2019-06-08 06:04:34 -06:00
depends on NET_DSA_SJA1105
help
This enables support for timestamping and PTP clock manipulations in
the SJA1105 DSA driver.
net: dsa: sja1105: Configure the Time-Aware Scheduler via tc-taprio offload This qdisc offload is the closest thing to what the SJA1105 supports in hardware for time-based egress shaping. The switch core really is built around SAE AS6802/TTEthernet (a TTTech standard) but can be made to operate similarly to IEEE 802.1Qbv with some constraints: - The gate control list is a global list for all ports. There are 8 execution threads that iterate through this global list in parallel. I don't know why 8, there are only 4 front-panel ports. - Care must be taken by the user to make sure that two execution threads never get to execute a GCL entry simultaneously. I created a O(n^4) checker for this hardware limitation, prior to accepting a taprio offload configuration as valid. - The spec says that if a GCL entry's interval is shorter than the frame length, you shouldn't send it (and end up in head-of-line blocking). Well, this switch does anyway. - The switch has no concept of ADMIN and OPER configurations. Because it's so simple, the TAS settings are loaded through the static config tables interface, so there isn't even place for any discussion about 'graceful switchover between ADMIN and OPER'. You just reset the switch and upload a new OPER config. - The switch accepts multiple time sources for the gate events. Right now I am using the standalone clock source as opposed to PTP. So the base time parameter doesn't really do much. Support for the PTP clock source will be added in a future series. Signed-off-by: Vladimir Oltean <olteanv@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2019-09-14 20:00:02 -06:00
config NET_DSA_SJA1105_TAS
bool "Support for the Time-Aware Scheduler on NXP SJA1105"
depends on NET_DSA_SJA1105 && NET_SCH_TAPRIO
depends on NET_SCH_TAPRIO=y || NET_DSA_SJA1105=m
net: dsa: sja1105: Configure the Time-Aware Scheduler via tc-taprio offload This qdisc offload is the closest thing to what the SJA1105 supports in hardware for time-based egress shaping. The switch core really is built around SAE AS6802/TTEthernet (a TTTech standard) but can be made to operate similarly to IEEE 802.1Qbv with some constraints: - The gate control list is a global list for all ports. There are 8 execution threads that iterate through this global list in parallel. I don't know why 8, there are only 4 front-panel ports. - Care must be taken by the user to make sure that two execution threads never get to execute a GCL entry simultaneously. I created a O(n^4) checker for this hardware limitation, prior to accepting a taprio offload configuration as valid. - The spec says that if a GCL entry's interval is shorter than the frame length, you shouldn't send it (and end up in head-of-line blocking). Well, this switch does anyway. - The switch has no concept of ADMIN and OPER configurations. Because it's so simple, the TAS settings are loaded through the static config tables interface, so there isn't even place for any discussion about 'graceful switchover between ADMIN and OPER'. You just reset the switch and upload a new OPER config. - The switch accepts multiple time sources for the gate events. Right now I am using the standalone clock source as opposed to PTP. So the base time parameter doesn't really do much. Support for the PTP clock source will be added in a future series. Signed-off-by: Vladimir Oltean <olteanv@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2019-09-14 20:00:02 -06:00
help
This enables support for the TTEthernet-based egress scheduling
engine in the SJA1105 DSA driver, which is controlled using a
hardware offload of the tc-tqprio qdisc.