1
0
Fork 0

hwmon: (lm90) Rearrange code to no longer require forward declarations

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Signed-off-by: Jean Delvare <khali@linux-fr.org>
hifive-unleashed-5.1
Guenter Roeck 2010-10-28 20:31:43 +02:00 committed by Jean Delvare
parent 06e1c0a216
commit 15b66ab690
1 changed files with 256 additions and 267 deletions

View File

@ -163,21 +163,6 @@ enum chips { lm90, adm1032, lm99, lm86, max6657, max6659, adt7461, max6680,
#define LM90_HAVE_EMERGENCY_ALARM (1 << 5)/* emergency alarm */
#define LM90_HAVE_TEMP3 (1 << 6) /* 3rd temperature sensor */
/*
* Functions declaration
*/
static int lm90_detect(struct i2c_client *client, struct i2c_board_info *info);
static int lm90_probe(struct i2c_client *client,
const struct i2c_device_id *id);
static void lm90_init_client(struct i2c_client *client);
static void lm90_alert(struct i2c_client *client, unsigned int flag);
static int lm90_remove(struct i2c_client *client);
static struct lm90_data *lm90_update_device(struct device *dev);
static inline void lm90_select_remote_channel(struct i2c_client *client,
struct lm90_data *data,
int channel);
/*
* Driver data (common to all clients)
*/
@ -204,19 +189,6 @@ static const struct i2c_device_id lm90_id[] = {
};
MODULE_DEVICE_TABLE(i2c, lm90_id);
static struct i2c_driver lm90_driver = {
.class = I2C_CLASS_HWMON,
.driver = {
.name = "lm90",
},
.probe = lm90_probe,
.remove = lm90_remove,
.alert = lm90_alert,
.id_table = lm90_id,
.detect = lm90_detect,
.address_list = normal_i2c,
};
/*
* Client data (each client gets its own)
*/
@ -255,6 +227,209 @@ struct lm90_data {
u16 alarms; /* bitvector (upper 8 bits for max6695/96) */
};
/*
* Support functions
*/
/*
* The ADM1032 supports PEC but not on write byte transactions, so we need
* to explicitly ask for a transaction without PEC.
*/
static inline s32 adm1032_write_byte(struct i2c_client *client, u8 value)
{
return i2c_smbus_xfer(client->adapter, client->addr,
client->flags & ~I2C_CLIENT_PEC,
I2C_SMBUS_WRITE, value, I2C_SMBUS_BYTE, NULL);
}
/*
* It is assumed that client->update_lock is held (unless we are in
* detection or initialization steps). This matters when PEC is enabled,
* because we don't want the address pointer to change between the write
* byte and the read byte transactions.
*/
static int lm90_read_reg(struct i2c_client *client, u8 reg, u8 *value)
{
int err;
if (client->flags & I2C_CLIENT_PEC) {
err = adm1032_write_byte(client, reg);
if (err >= 0)
err = i2c_smbus_read_byte(client);
} else
err = i2c_smbus_read_byte_data(client, reg);
if (err < 0) {
dev_warn(&client->dev, "Register %#02x read failed (%d)\n",
reg, err);
return err;
}
*value = err;
return 0;
}
static int lm90_read16(struct i2c_client *client, u8 regh, u8 regl, u16 *value)
{
int err;
u8 oldh, newh, l;
/*
* There is a trick here. We have to read two registers to have the
* sensor temperature, but we have to beware a conversion could occur
* inbetween the readings. The datasheet says we should either use
* the one-shot conversion register, which we don't want to do
* (disables hardware monitoring) or monitor the busy bit, which is
* impossible (we can't read the values and monitor that bit at the
* exact same time). So the solution used here is to read the high
* byte once, then the low byte, then the high byte again. If the new
* high byte matches the old one, then we have a valid reading. Else
* we have to read the low byte again, and now we believe we have a
* correct reading.
*/
if ((err = lm90_read_reg(client, regh, &oldh))
|| (err = lm90_read_reg(client, regl, &l))
|| (err = lm90_read_reg(client, regh, &newh)))
return err;
if (oldh != newh) {
err = lm90_read_reg(client, regl, &l);
if (err)
return err;
}
*value = (newh << 8) | l;
return 0;
}
/*
* client->update_lock must be held when calling this function (unless we are
* in detection or initialization steps), and while a remote channel other
* than channel 0 is selected. Also, calling code must make sure to re-select
* external channel 0 before releasing the lock. This is necessary because
* various registers have different meanings as a result of selecting a
* non-default remote channel.
*/
static inline void lm90_select_remote_channel(struct i2c_client *client,
struct lm90_data *data,
int channel)
{
u8 config;
if (data->kind == max6696) {
lm90_read_reg(client, LM90_REG_R_CONFIG1, &config);
config &= ~0x08;
if (channel)
config |= 0x08;
i2c_smbus_write_byte_data(client, LM90_REG_W_CONFIG1,
config);
}
}
static struct lm90_data *lm90_update_device(struct device *dev)
{
struct i2c_client *client = to_i2c_client(dev);
struct lm90_data *data = i2c_get_clientdata(client);
mutex_lock(&data->update_lock);
if (time_after(jiffies, data->last_updated + HZ / 2 + HZ / 10)
|| !data->valid) {
u8 h, l;
u8 alarms;
dev_dbg(&client->dev, "Updating lm90 data.\n");
lm90_read_reg(client, LM90_REG_R_LOCAL_LOW, &data->temp8[0]);
lm90_read_reg(client, LM90_REG_R_LOCAL_HIGH, &data->temp8[1]);
lm90_read_reg(client, LM90_REG_R_LOCAL_CRIT, &data->temp8[2]);
lm90_read_reg(client, LM90_REG_R_REMOTE_CRIT, &data->temp8[3]);
lm90_read_reg(client, LM90_REG_R_TCRIT_HYST, &data->temp_hyst);
if (data->flags & LM90_HAVE_LOCAL_EXT) {
lm90_read16(client, LM90_REG_R_LOCAL_TEMP,
MAX6657_REG_R_LOCAL_TEMPL,
&data->temp11[4]);
} else {
if (lm90_read_reg(client, LM90_REG_R_LOCAL_TEMP,
&h) == 0)
data->temp11[4] = h << 8;
}
lm90_read16(client, LM90_REG_R_REMOTE_TEMPH,
LM90_REG_R_REMOTE_TEMPL, &data->temp11[0]);
if (lm90_read_reg(client, LM90_REG_R_REMOTE_LOWH, &h) == 0) {
data->temp11[1] = h << 8;
if ((data->flags & LM90_HAVE_REM_LIMIT_EXT)
&& lm90_read_reg(client, LM90_REG_R_REMOTE_LOWL,
&l) == 0)
data->temp11[1] |= l;
}
if (lm90_read_reg(client, LM90_REG_R_REMOTE_HIGHH, &h) == 0) {
data->temp11[2] = h << 8;
if ((data->flags & LM90_HAVE_REM_LIMIT_EXT)
&& lm90_read_reg(client, LM90_REG_R_REMOTE_HIGHL,
&l) == 0)
data->temp11[2] |= l;
}
if (data->flags & LM90_HAVE_OFFSET) {
if (lm90_read_reg(client, LM90_REG_R_REMOTE_OFFSH,
&h) == 0
&& lm90_read_reg(client, LM90_REG_R_REMOTE_OFFSL,
&l) == 0)
data->temp11[3] = (h << 8) | l;
}
if (data->flags & LM90_HAVE_EMERGENCY) {
lm90_read_reg(client, MAX6659_REG_R_LOCAL_EMERG,
&data->temp8[4]);
lm90_read_reg(client, MAX6659_REG_R_REMOTE_EMERG,
&data->temp8[5]);
}
lm90_read_reg(client, LM90_REG_R_STATUS, &alarms);
data->alarms = alarms; /* save as 16 bit value */
if (data->kind == max6696) {
lm90_select_remote_channel(client, data, 1);
lm90_read_reg(client, LM90_REG_R_REMOTE_CRIT,
&data->temp8[6]);
lm90_read_reg(client, MAX6659_REG_R_REMOTE_EMERG,
&data->temp8[7]);
lm90_read16(client, LM90_REG_R_REMOTE_TEMPH,
LM90_REG_R_REMOTE_TEMPL, &data->temp11[5]);
if (!lm90_read_reg(client, LM90_REG_R_REMOTE_LOWH, &h))
data->temp11[6] = h << 8;
if (!lm90_read_reg(client, LM90_REG_R_REMOTE_HIGHH, &h))
data->temp11[7] = h << 8;
lm90_select_remote_channel(client, data, 0);
if (!lm90_read_reg(client, MAX6696_REG_R_STATUS2,
&alarms))
data->alarms |= alarms << 8;
}
/* Re-enable ALERT# output if it was originally enabled and
* relevant alarms are all clear */
if ((data->config_orig & 0x80) == 0
&& (data->alarms & data->alert_alarms) == 0) {
u8 config;
lm90_read_reg(client, LM90_REG_R_CONFIG1, &config);
if (config & 0x80) {
dev_dbg(&client->dev, "Re-enabling ALERT#\n");
i2c_smbus_write_byte_data(client,
LM90_REG_W_CONFIG1,
config & ~0x80);
}
}
data->last_updated = jiffies;
data->valid = 1;
}
mutex_unlock(&data->update_lock);
return data;
}
/*
* Conversions
* For local temperatures and limits, critical limits and the hysteresis
@ -770,68 +945,6 @@ static DEVICE_ATTR(pec, S_IWUSR | S_IRUGO, show_pec, set_pec);
* Real code
*/
/*
* The ADM1032 supports PEC but not on write byte transactions, so we need
* to explicitly ask for a transaction without PEC.
*/
static inline s32 adm1032_write_byte(struct i2c_client *client, u8 value)
{
return i2c_smbus_xfer(client->adapter, client->addr,
client->flags & ~I2C_CLIENT_PEC,
I2C_SMBUS_WRITE, value, I2C_SMBUS_BYTE, NULL);
}
/*
* It is assumed that client->update_lock is held (unless we are in
* detection or initialization steps). This matters when PEC is enabled,
* because we don't want the address pointer to change between the write
* byte and the read byte transactions.
*/
static int lm90_read_reg(struct i2c_client *client, u8 reg, u8 *value)
{
int err;
if (client->flags & I2C_CLIENT_PEC) {
err = adm1032_write_byte(client, reg);
if (err >= 0)
err = i2c_smbus_read_byte(client);
} else
err = i2c_smbus_read_byte_data(client, reg);
if (err < 0) {
dev_warn(&client->dev, "Register %#02x read failed (%d)\n",
reg, err);
return err;
}
*value = err;
return 0;
}
/*
* client->update_lock must be held when calling this function (unless we are
* in detection or initialization steps), and while a remote channel other
* than channel 0 is selected. Also, calling code must make sure to re-select
* external channel 0 before releasing the lock. This is necessary because
* various registers have different meanings as a result of selecting a
* non-default remote channel.
*/
static inline void lm90_select_remote_channel(struct i2c_client *client,
struct lm90_data *data,
int channel)
{
u8 config;
if (data->kind == max6696) {
lm90_read_reg(client, LM90_REG_R_CONFIG1, &config);
config &= ~0x08;
if (channel)
config |= 0x08;
i2c_smbus_write_byte_data(client, LM90_REG_W_CONFIG1,
config);
}
}
/* Return 0 if detection is successful, -ENODEV otherwise */
static int lm90_detect(struct i2c_client *new_client,
struct i2c_board_info *info)
@ -1023,6 +1136,47 @@ static void lm90_remove_files(struct i2c_client *client, struct lm90_data *data)
sysfs_remove_group(&client->dev.kobj, &lm90_group);
}
static void lm90_init_client(struct i2c_client *client)
{
u8 config;
struct lm90_data *data = i2c_get_clientdata(client);
/*
* Start the conversions.
*/
i2c_smbus_write_byte_data(client, LM90_REG_W_CONVRATE,
5); /* 2 Hz */
if (lm90_read_reg(client, LM90_REG_R_CONFIG1, &config) < 0) {
dev_warn(&client->dev, "Initialization failed!\n");
return;
}
data->config_orig = config;
/* Check Temperature Range Select */
if (data->kind == adt7461) {
if (config & 0x04)
data->flags |= LM90_FLAG_ADT7461_EXT;
}
/*
* Put MAX6680/MAX8881 into extended resolution (bit 0x10,
* 0.125 degree resolution) and range (0x08, extend range
* to -64 degree) mode for the remote temperature sensor.
*/
if (data->kind == max6680)
config |= 0x18;
/*
* Select external channel 0 for max6695/96
*/
if (data->kind == max6696)
config &= ~0x08;
config &= 0xBF; /* run */
if (config != data->config_orig) /* Only write if changed */
i2c_smbus_write_byte_data(client, LM90_REG_W_CONFIG1, config);
}
static int lm90_probe(struct i2c_client *new_client,
const struct i2c_device_id *id)
{
@ -1134,47 +1288,6 @@ exit:
return err;
}
static void lm90_init_client(struct i2c_client *client)
{
u8 config;
struct lm90_data *data = i2c_get_clientdata(client);
/*
* Start the conversions.
*/
i2c_smbus_write_byte_data(client, LM90_REG_W_CONVRATE,
5); /* 2 Hz */
if (lm90_read_reg(client, LM90_REG_R_CONFIG1, &config) < 0) {
dev_warn(&client->dev, "Initialization failed!\n");
return;
}
data->config_orig = config;
/* Check Temperature Range Select */
if (data->kind == adt7461) {
if (config & 0x04)
data->flags |= LM90_FLAG_ADT7461_EXT;
}
/*
* Put MAX6680/MAX8881 into extended resolution (bit 0x10,
* 0.125 degree resolution) and range (0x08, extend range
* to -64 degree) mode for the remote temperature sensor.
*/
if (data->kind == max6680)
config |= 0x18;
/*
* Select external channel 0 for max6695/96
*/
if (data->kind == max6696)
config &= ~0x08;
config &= 0xBF; /* run */
if (config != data->config_orig) /* Only write if changed */
i2c_smbus_write_byte_data(client, LM90_REG_W_CONFIG1, config);
}
static int lm90_remove(struct i2c_client *client)
{
struct lm90_data *data = i2c_get_clientdata(client);
@ -1230,142 +1343,18 @@ static void lm90_alert(struct i2c_client *client, unsigned int flag)
}
}
static int lm90_read16(struct i2c_client *client, u8 regh, u8 regl, u16 *value)
{
int err;
u8 oldh, newh, l;
/*
* There is a trick here. We have to read two registers to have the
* sensor temperature, but we have to beware a conversion could occur
* inbetween the readings. The datasheet says we should either use
* the one-shot conversion register, which we don't want to do
* (disables hardware monitoring) or monitor the busy bit, which is
* impossible (we can't read the values and monitor that bit at the
* exact same time). So the solution used here is to read the high
* byte once, then the low byte, then the high byte again. If the new
* high byte matches the old one, then we have a valid reading. Else
* we have to read the low byte again, and now we believe we have a
* correct reading.
*/
if ((err = lm90_read_reg(client, regh, &oldh))
|| (err = lm90_read_reg(client, regl, &l))
|| (err = lm90_read_reg(client, regh, &newh)))
return err;
if (oldh != newh) {
err = lm90_read_reg(client, regl, &l);
if (err)
return err;
}
*value = (newh << 8) | l;
return 0;
}
static struct lm90_data *lm90_update_device(struct device *dev)
{
struct i2c_client *client = to_i2c_client(dev);
struct lm90_data *data = i2c_get_clientdata(client);
mutex_lock(&data->update_lock);
if (time_after(jiffies, data->last_updated + HZ / 2 + HZ / 10)
|| !data->valid) {
u8 h, l;
u8 alarms;
dev_dbg(&client->dev, "Updating lm90 data.\n");
lm90_read_reg(client, LM90_REG_R_LOCAL_LOW, &data->temp8[0]);
lm90_read_reg(client, LM90_REG_R_LOCAL_HIGH, &data->temp8[1]);
lm90_read_reg(client, LM90_REG_R_LOCAL_CRIT, &data->temp8[2]);
lm90_read_reg(client, LM90_REG_R_REMOTE_CRIT, &data->temp8[3]);
lm90_read_reg(client, LM90_REG_R_TCRIT_HYST, &data->temp_hyst);
if (data->flags & LM90_HAVE_LOCAL_EXT) {
lm90_read16(client, LM90_REG_R_LOCAL_TEMP,
MAX6657_REG_R_LOCAL_TEMPL,
&data->temp11[4]);
} else {
if (lm90_read_reg(client, LM90_REG_R_LOCAL_TEMP,
&h) == 0)
data->temp11[4] = h << 8;
}
lm90_read16(client, LM90_REG_R_REMOTE_TEMPH,
LM90_REG_R_REMOTE_TEMPL, &data->temp11[0]);
if (lm90_read_reg(client, LM90_REG_R_REMOTE_LOWH, &h) == 0) {
data->temp11[1] = h << 8;
if ((data->flags & LM90_HAVE_REM_LIMIT_EXT)
&& lm90_read_reg(client, LM90_REG_R_REMOTE_LOWL,
&l) == 0)
data->temp11[1] |= l;
}
if (lm90_read_reg(client, LM90_REG_R_REMOTE_HIGHH, &h) == 0) {
data->temp11[2] = h << 8;
if ((data->flags & LM90_HAVE_REM_LIMIT_EXT)
&& lm90_read_reg(client, LM90_REG_R_REMOTE_HIGHL,
&l) == 0)
data->temp11[2] |= l;
}
if (data->flags & LM90_HAVE_OFFSET) {
if (lm90_read_reg(client, LM90_REG_R_REMOTE_OFFSH,
&h) == 0
&& lm90_read_reg(client, LM90_REG_R_REMOTE_OFFSL,
&l) == 0)
data->temp11[3] = (h << 8) | l;
}
if (data->flags & LM90_HAVE_EMERGENCY) {
lm90_read_reg(client, MAX6659_REG_R_LOCAL_EMERG,
&data->temp8[4]);
lm90_read_reg(client, MAX6659_REG_R_REMOTE_EMERG,
&data->temp8[5]);
}
lm90_read_reg(client, LM90_REG_R_STATUS, &alarms);
data->alarms = alarms; /* save as 16 bit value */
if (data->kind == max6696) {
lm90_select_remote_channel(client, data, 1);
lm90_read_reg(client, LM90_REG_R_REMOTE_CRIT,
&data->temp8[6]);
lm90_read_reg(client, MAX6659_REG_R_REMOTE_EMERG,
&data->temp8[7]);
lm90_read16(client, LM90_REG_R_REMOTE_TEMPH,
LM90_REG_R_REMOTE_TEMPL, &data->temp11[5]);
if (!lm90_read_reg(client, LM90_REG_R_REMOTE_LOWH, &h))
data->temp11[6] = h << 8;
if (!lm90_read_reg(client, LM90_REG_R_REMOTE_HIGHH, &h))
data->temp11[7] = h << 8;
lm90_select_remote_channel(client, data, 0);
if (!lm90_read_reg(client, MAX6696_REG_R_STATUS2,
&alarms))
data->alarms |= alarms << 8;
}
/* Re-enable ALERT# output if it was originally enabled and
* relevant alarms are all clear */
if ((data->config_orig & 0x80) == 0
&& (data->alarms & data->alert_alarms) == 0) {
u8 config;
lm90_read_reg(client, LM90_REG_R_CONFIG1, &config);
if (config & 0x80) {
dev_dbg(&client->dev, "Re-enabling ALERT#\n");
i2c_smbus_write_byte_data(client,
LM90_REG_W_CONFIG1,
config & ~0x80);
}
}
data->last_updated = jiffies;
data->valid = 1;
}
mutex_unlock(&data->update_lock);
return data;
}
static struct i2c_driver lm90_driver = {
.class = I2C_CLASS_HWMON,
.driver = {
.name = "lm90",
},
.probe = lm90_probe,
.remove = lm90_remove,
.alert = lm90_alert,
.id_table = lm90_id,
.detect = lm90_detect,
.address_list = normal_i2c,
};
static int __init sensors_lm90_init(void)
{