1
0
Fork 0

serial: mcf: fix no driver name in probe output

The current output of the device probing looks like this:

ColdFire internal UART serial driver
(NULL device *): ttyS0 at MMIO 0xfc060000 (irq = 90, base_baud = 5208333) is a ColdFire UART
console [ttyS0] enabled
(NULL device *): ttyS1 at MMIO 0xfc064000 (irq = 91, base_baud = 5208333) is a ColdFire UART
(NULL device *): ttyS2 at MMIO 0xfc068000 (irq = 92, base_baud = 5208333) is a ColdFire UART

Fix the port device linkage at probing time so that the device name is
printed out properly, and not "(NULL device *)".

Signed-off-by: Greg Ungerer <gerg@uclinux.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
hifive-unleashed-5.1
Greg Ungerer 2015-01-08 14:19:51 +10:00 committed by Greg Kroah-Hartman
parent ebffbc6cdb
commit 201d8975ae
1 changed files with 1 additions and 0 deletions

View File

@ -629,6 +629,7 @@ static int mcf_probe(struct platform_device *pdev)
port->mapbase = platp[i].mapbase;
port->membase = (platp[i].membase) ? platp[i].membase :
(unsigned char __iomem *) platp[i].mapbase;
port->dev = &pdev->dev;
port->iotype = SERIAL_IO_MEM;
port->irq = platp[i].irq;
port->uartclk = MCF_BUSCLK;