ARM: dts: imx7d: Add missing cooling device properties for CPUs

The cooling device properties "#cooling-cells" should either be present
for all the CPUs of a cluster or none. If these are present only for a
subset of CPUs of a cluster then things will start falling apart as soon
as the CPUs are brought online in a different order. For example, this
will happen because the operating system looks for such properties in the
CPU node it is trying to bring up, so that it can register a cooling
device.

Add such missing properties.

Signed-off-by: Anson Huang <Anson.Huang@nxp.com>
Signed-off-by: Shawn Guo <shawnguo@kernel.org>
This commit is contained in:
Anson Huang 2019-10-24 10:34:25 +08:00 committed by Shawn Guo
parent def76ebc7c
commit 28e95b7dcc

View file

@ -22,6 +22,7 @@
reg = <1>;
clock-frequency = <996000000>;
operating-points-v2 = <&cpu0_opp_table>;
#cooling-cells = <2>;
cpu-idle-states = <&cpu_sleep_wait>;
};
};