staging: iio: ad7780: update voltage on read

The ad7780 driver previously did not read the correct device output, as
it read an outdated value set at initialization. It now updates its
voltage on read.

Signed-off-by: Renato Lui Geh <renatogeh@gmail.com>
Acked-by: Alexandru Ardelean <alexandru.ardelean@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
Renato Lui Geh 2018-11-05 17:14:58 -02:00 committed by Jonathan Cameron
parent 121354b2ec
commit 336650c785

View file

@ -96,12 +96,16 @@ static int ad7780_read_raw(struct iio_dev *indio_dev,
long m)
{
struct ad7780_state *st = iio_priv(indio_dev);
int voltage_uv;
switch (m) {
case IIO_CHAN_INFO_RAW:
return ad_sigma_delta_single_conversion(indio_dev, chan, val);
case IIO_CHAN_INFO_SCALE:
*val = st->int_vref_mv * st->gain;
voltage_uv = regulator_get_voltage(st->reg);
if (voltage_uv < 0)
return voltage_uv;
*val = (voltage_uv / 1000) * st->gain;
*val2 = chan->scan_type.realbits - 1;
return IIO_VAL_FRACTIONAL_LOG2;
case IIO_CHAN_INFO_OFFSET: