iio:humidity:si7020: cleanup read_raw and probe

When reading temperature or humidity values, a shift of two bits to the right
needs to be applied, and only for the humidity channel a mask of the lower
12 bits needs to be applied. This reduces code repetition.
During probe, i2c_set_clientdata() was used, although its counterpart was not,
so drop it.

Signed-off-by: Hartmut Knaack <knaack.h@gmx.de>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This commit is contained in:
Hartmut Knaack 2014-10-25 20:09:11 +02:00 committed by Jonathan Cameron
parent acd8256723
commit 345b48307d

View file

@ -56,10 +56,9 @@ static int si7020_read_raw(struct iio_dev *indio_dev,
SI7020CMD_RH_HOLD);
if (ret < 0)
return ret;
if (chan->type == IIO_TEMP)
*val = ret >> 2;
else
*val = (ret & 0x3FFF) >> 2;
*val = ret >> 2;
if (chan->type == IIO_HUMIDITYRELATIVE)
*val &= GENMASK(11, 0);
return IIO_VAL_INT;
case IIO_CHAN_INFO_SCALE:
if (chan->type == IIO_TEMP)
@ -133,7 +132,6 @@ static int si7020_probe(struct i2c_client *client,
data = iio_priv(indio_dev);
*data = client;
i2c_set_clientdata(client, indio_dev);
indio_dev->dev.parent = &client->dev;
indio_dev->name = dev_name(&client->dev);