1
0
Fork 0

spi-topcliff-pch: Fix CPU read complete condition issue

We found Rx data sometimes drops.(with non-DMA transfer mode)
The cause is read complete condition is not true.

This patch fixes the issue.

Signed-off-by: Tomoya MORINAGA <tomoya-linux@dsn.okisemi.com>
Signed-off-by: Grant Likely <grant.likely@secretlab.ca>
hifive-unleashed-5.1
Tomoya MORINAGA 2011-09-06 17:16:36 +09:00 committed by Grant Likely
parent 8b7aa961a8
commit 373b0eb64b
1 changed files with 11 additions and 8 deletions

View File

@ -317,16 +317,19 @@ static void pch_spi_handler_sub(struct pch_spi_data *data, u32 reg_spsr_val,
/* if transfer complete interrupt */
if (reg_spsr_val & SPSR_FI_BIT) {
if (tx_index < bpw_len)
if ((tx_index == bpw_len) && (rx_index == tx_index)) {
/* disable interrupts */
pch_spi_setclr_reg(data->master, PCH_SPCR, 0, PCH_ALL);
/* transfer is completed;
inform pch_spi_process_messages */
data->transfer_complete = true;
data->transfer_active = false;
wake_up(&data->wait);
} else {
dev_err(&data->master->dev,
"%s : Transfer is not completed", __func__);
/* disable interrupts */
pch_spi_setclr_reg(data->master, PCH_SPCR, 0, PCH_ALL);
/* transfer is completed;inform pch_spi_process_messages */
data->transfer_complete = true;
data->transfer_active = false;
wake_up(&data->wait);
}
}
}