1
0
Fork 0

reset: Fix of_reset_control_get() for consistent return values

When of_reset_control_get() is called without connection ID it returns
-ENOENT when the 'resets' property doesn't exists or is an empty entry.
However when a connection ID is given it returns -EINVAL when the 'resets'
property doesn't exists or the requested name can't be found. This is
because the error code returned by of_property_match_string() is just
passed down as an index to of_parse_phandle_with_args(), which then
returns -EINVAL.

To get a consistent return value with both code paths we must return
-ENOENT when of_property_match_string() fails.

Signed-off-by: Alban Bedel <albeu@free.fr>
Signed-off-by: Philipp Zabel <p.zabel@pengutronix.de>
hifive-unleashed-5.1
Alban Bedel 2015-09-01 17:28:31 +02:00 committed by Philipp Zabel
parent c0a13aa6da
commit 3d81216fde
1 changed files with 4 additions and 1 deletions

View File

@ -215,9 +215,12 @@ struct reset_control *of_reset_control_get(struct device_node *node,
{
int index = 0;
if (id)
if (id) {
index = of_property_match_string(node,
"reset-names", id);
if (index < 0)
return ERR_PTR(-ENOENT);
}
return of_reset_control_get_by_index(node, index);
}
EXPORT_SYMBOL_GPL(of_reset_control_get);