iio/gyro/bmg160: Use millidegrees for temperature scale

Standard unit for temperature is millidegrees Celcius, whereas this driver
was reporting in degrees. Fix the scale factor in the driver.

Signed-off-by: Mike Looijmans <mike.looijmans@topic.nl>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
hifive-unleashed-5.1
Mike Looijmans 2019-02-13 08:41:47 +01:00 committed by Jonathan Cameron
parent 0a8a29be49
commit 40a7198a4a
1 changed files with 3 additions and 3 deletions

View File

@ -582,11 +582,10 @@ static int bmg160_read_raw(struct iio_dev *indio_dev,
case IIO_CHAN_INFO_LOW_PASS_FILTER_3DB_FREQUENCY:
return bmg160_get_filter(data, val);
case IIO_CHAN_INFO_SCALE:
*val = 0;
switch (chan->type) {
case IIO_TEMP:
*val2 = 500000;
return IIO_VAL_INT_PLUS_MICRO;
*val = 500;
return IIO_VAL_INT;
case IIO_ANGL_VEL:
{
int i;
@ -594,6 +593,7 @@ static int bmg160_read_raw(struct iio_dev *indio_dev,
for (i = 0; i < ARRAY_SIZE(bmg160_scale_table); ++i) {
if (bmg160_scale_table[i].dps_range ==
data->dps_range) {
*val = 0;
*val2 = bmg160_scale_table[i].scale;
return IIO_VAL_INT_PLUS_MICRO;
}