1
0
Fork 0

s390/cio: clear timer when terminating driver I/O

When we terminate driver I/O (because we need to stop using a certain
channel path) we also need to ensure that a timer (which may have been
set up using ccw_device_start_timeout) is cleared.

Signed-off-by: Sebastian Ott <sebott@linux.vnet.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
hifive-unleashed-5.1
Sebastian Ott 2018-02-12 12:01:03 +01:00 committed by Martin Schwidefsky
parent 770b55c995
commit 410d5e13e7
1 changed files with 1 additions and 0 deletions

View File

@ -896,6 +896,7 @@ void ccw_device_kill_io(struct ccw_device *cdev)
{
int ret;
ccw_device_set_timeout(cdev, 0);
cdev->private->iretry = 255;
cdev->private->async_kill_io_rc = -EIO;
ret = ccw_device_cancel_halt_clear(cdev);