b43: N-PHY: Fix the update of coef for the PHY revision >= 3case

The documentation for the PHY update [1] states:

Loop 4 times with index i

    If PHY Revision >= 3
        Copy table[i] to coef[i]
    Otherwise
        Set coef[i] to 0

the copy of the table to coef is currently implemented the wrong way
around, table is being updated from uninitialized values in coeff.
Fix this by swapping the assignment around.

[1] https://bcm-v4.sipsolutions.net/802.11/PHY/N/RestoreCal/

Fixes: 2f258b74d1 ("b43: N-PHY: implement restoring general configuration")
Addresses-Coverity: ("Uninitialized scalar variable")
Signed-off-by: Colin Ian King <colin.king@canonical.com>
Acked-by: Larry Finger <Larry.Finger@lwfinger.net>
Signed-off-by: David S. Miller <davem@davemloft.net>
master
Colin Ian King 2021-02-15 12:05:32 +00:00 committed by David S. Miller
parent 2355a6773a
commit 4773acf3d4
1 changed files with 1 additions and 1 deletions

View File

@ -5311,7 +5311,7 @@ static void b43_nphy_restore_cal(struct b43_wldev *dev)
for (i = 0; i < 4; i++) {
if (dev->phy.rev >= 3)
table[i] = coef[i];
coef[i] = table[i];
else
coef[i] = 0;
}