1
0
Fork 0

regulator: Only apply voltage constraints from consumers that set them

When applying the set_voltage() requests from consumers skip over those
consumers that haven't set anything, otherwise we'll come out with a
maximum voltage of zero.

Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
hifive-unleashed-5.1
Mark Brown 2011-05-14 13:42:34 -07:00 committed by Liam Girdwood
parent a4b4148379
commit 4aa922c024
1 changed files with 7 additions and 0 deletions

View File

@ -158,6 +158,13 @@ static int regulator_check_consumers(struct regulator_dev *rdev,
struct regulator *regulator;
list_for_each_entry(regulator, &rdev->consumer_list, list) {
/*
* Assume consumers that didn't say anything are OK
* with anything in the constraint range.
*/
if (!regulator->min_uV && !regulator->max_uV)
continue;
if (*max_uV > regulator->max_uV)
*max_uV = regulator->max_uV;
if (*min_uV < regulator->min_uV)