MLK-22879-01 clk: imx: Add no cached flag for dram pll
When doing DRAM frequency change, the DRAM PLL config will be changed in ATF side, so add 'CLK_GET_RATE_NOCACHE' flag to make sure each time we get the DRAM PLL frequency through 'clk_get_rate' API, we can get the correct frequency. Signed-off-by: Jacky Bai <ping.bai@nxp.com> Reviewed-by: Anson Huang <anson.huang@nxp.com> Reviewed-by: Robin Gong <yibin.gong@nxp.com>5.4-rM2-2.2.x-imx-squashed
parent
7e99bce2f6
commit
5c68287d6c
|
@ -69,6 +69,7 @@ static struct imx_pll14xx_clk imx8mm_dram_pll = {
|
|||
.type = PLL_1443X,
|
||||
.rate_table = imx8mm_drampll_tbl,
|
||||
.rate_count = ARRAY_SIZE(imx8mm_drampll_tbl),
|
||||
.flags = CLK_GET_RATE_NOCACHE,
|
||||
};
|
||||
|
||||
static struct imx_pll14xx_clk imx8mm_arm_pll = {
|
||||
|
|
|
@ -84,6 +84,7 @@ static struct imx_pll14xx_clk imx8mn_dram_pll = {
|
|||
.type = PLL_1443X,
|
||||
.rate_table = imx8mn_drampll_tbl,
|
||||
.rate_count = ARRAY_SIZE(imx8mn_drampll_tbl),
|
||||
.flags = CLK_GET_RATE_NOCACHE,
|
||||
};
|
||||
|
||||
static struct imx_pll14xx_clk imx8mn_arm_pll = {
|
||||
|
|
Loading…