hwmon: (smsc47m192) Fix overflows seen when writing into limit attributes

Module test reports overflows when writing into temperature and voltage
limit attributes

temp1_min: Suspected overflow: [127000 vs. 0]
temp1_max: Suspected overflow: [127000 vs. 0]
temp1_offset: Suspected overflow: [127000 vs. 0]
temp2_min: Suspected overflow: [127000 vs. 0]
temp2_max: Suspected overflow: [127000 vs. 0]
temp2_offset: Suspected overflow: [127000 vs. 0]
temp3_min: Suspected overflow: [127000 vs. 0]
temp3_max: Suspected overflow: [127000 vs. 0]
temp3_offset: Suspected overflow: [127000 vs. 0]
in0_min: Suspected overflow: [3320 vs. 0]
in0_max: Suspected overflow: [3320 vs. 0]
in4_min: Suspected overflow: [15938 vs. 0]
in4_max: Suspected overflow: [15938 vs. 0]
in6_min: Suspected overflow: [1992 vs. 0]
in6_max: Suspected overflow: [1992 vs. 0]
in7_min: Suspected overflow: [2391 vs. 0]
in7_max: Suspected overflow: [2391 vs. 0]

The problem is caused by conversions from unsigned long to long and
from long to int.

Reviewed-by: Jean Delvare <jdelvare@suse.de>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
hifive-unleashed-5.1
Guenter Roeck 2016-11-20 14:16:16 -08:00
parent e36ce99ee0
commit 78305ae70c
1 changed files with 3 additions and 2 deletions

View File

@ -77,14 +77,15 @@ static inline unsigned int IN_FROM_REG(u8 reg, int n)
static inline u8 IN_TO_REG(unsigned long val, int n)
{
return clamp_val(SCALE(val, 192, nom_mv[n]), 0, 255);
val = clamp_val(val, 0, nom_mv[n] * 255 / 192);
return SCALE(val, 192, nom_mv[n]);
}
/*
* TEMP: 0.001 degC units (-128C to +127C)
* REG: 1C/bit, two's complement
*/
static inline s8 TEMP_TO_REG(int val)
static inline s8 TEMP_TO_REG(long val)
{
return SCALE(clamp_val(val, -128000, 127000), 1, 1000);
}