1
0
Fork 0

dmaengine/amba-pl08x : reset phychan_hold on terminate all

When a client calls pl08x_control with DMA_TERMINATE_ALL, it is correct
to terminate and release the phy channel currently in use (if one is in use),
but the phychan_hold counter must also be reset (otherwise it could get
trapped in an unbalanced state).

Signed-off-by: Davide Ciminaghi <ciminaghi@gnudd.com>
Reviewed-by: Viresh Kumar <viresh.kumar@st.com>
Acked-by: Linus Walleij <linus.walleij@linaro.org>
Signed-off-by: Vinod Koul <vinod.koul@linux.intel.com>
hifive-unleashed-5.1
Davide Ciminaghi 2012-04-19 12:20:24 +02:00 committed by Vinod Koul
parent c847382838
commit 88c08a3fba
1 changed files with 1 additions and 0 deletions

View File

@ -1429,6 +1429,7 @@ static int pl08x_control(struct dma_chan *chan, enum dma_ctrl_cmd cmd,
* signal
*/
release_phy_channel(plchan);
plchan->phychan_hold = 0;
}
/* Dequeue jobs and free LLIs */
if (plchan->at) {