PowerCap: Fix mode for energy counter

As per the documentation of powercap sysfs, energy_uj field is read only,
if it can't be reset. Currently it always allows write but will fail,
if there is no reset callback.
Changing mode field, to read only if there is no reset callback.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Reported-by: Dirk Brandewie <dirk.j.brandewie@intel.com>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
hifive-unleashed-5.1
Srinivas Pandruvada 2013-12-04 11:12:59 -08:00 committed by Rafael J. Wysocki
parent 08ff4cbe10
commit 95677a9a38
1 changed files with 6 additions and 1 deletions

View File

@ -377,9 +377,14 @@ static void create_power_zone_common_attributes(
if (power_zone->ops->get_max_energy_range_uj)
power_zone->zone_dev_attrs[count++] =
&dev_attr_max_energy_range_uj.attr;
if (power_zone->ops->get_energy_uj)
if (power_zone->ops->get_energy_uj) {
if (power_zone->ops->reset_energy_uj)
dev_attr_energy_uj.attr.mode = S_IWUSR | S_IRUGO;
else
dev_attr_energy_uj.attr.mode = S_IRUGO;
power_zone->zone_dev_attrs[count++] =
&dev_attr_energy_uj.attr;
}
if (power_zone->ops->get_power_uw)
power_zone->zone_dev_attrs[count++] =
&dev_attr_power_uw.attr;