ASoC: cs4270: fix Master Capture Switch polarity

The control modifies the MUTE register, hence the polarity must be
inverted.

Signed-off-by: Daniel Mack <daniel@caiaq.de>
Acked-By: Timur Tabi <timur@freescale.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This commit is contained in:
Daniel Mack 2009-04-24 15:00:25 +02:00 committed by Mark Brown
parent 0b5e92c5e0
commit 9c93538651

View file

@ -486,7 +486,7 @@ static const struct snd_kcontrol_new cs4270_snd_controls[] = {
SOC_SINGLE("Zero Cross Switch", CS4270_TRANS, 5, 1, 0),
SOC_SINGLE("Popguard Switch", CS4270_MODE, 0, 1, 1),
SOC_SINGLE("Auto-Mute Switch", CS4270_MUTE, 5, 1, 0),
SOC_DOUBLE("Master Capture Switch", CS4270_MUTE, 3, 4, 1, 0)
SOC_DOUBLE("Master Capture Switch", CS4270_MUTE, 3, 4, 1, 1)
};
/*