1
0
Fork 0

usb: dwc3: remove generic PHY calibrate() calls

Calls to USB2 generic PHY calibrate() method has been moved to HCD core,
which now successfully handles generic PHYs and their calibration after
every HCD reset. This fixes all the timing issues related to PHY
calibration done directly from DWC3 driver: incorrect operation after
system suspend/resume or USB3.0 detection failure when XHCI-plat driver
compiled as separate module.

Signed-off-by: Marek Szyprowski <m.szyprowski@samsung.com>
Tested-by: Anand Moon <linux.amoon@gmail.com>
Tested-by: Jochen Sprickerhof <jochen@sprickerhof.de>
Acked-by: Felipe Balbi <felipe.balbi@linux.intel.com>
Link: https://lore.kernel.org/r/20190829053028.32438-3-m.szyprowski@samsung.com
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
alistair/sunxi64-5.4-dsi
Marek Szyprowski 2019-08-29 07:30:28 +02:00 committed by Greg Kroah-Hartman
parent 34c7ed72f4
commit a0a465569b
1 changed files with 0 additions and 2 deletions

View File

@ -168,7 +168,6 @@ static void __dwc3_set_mode(struct work_struct *work)
otg_set_vbus(dwc->usb2_phy->otg, true);
phy_set_mode(dwc->usb2_generic_phy, PHY_MODE_USB_HOST);
phy_set_mode(dwc->usb3_generic_phy, PHY_MODE_USB_HOST);
phy_calibrate(dwc->usb2_generic_phy);
}
break;
case DWC3_GCTL_PRTCAP_DEVICE:
@ -1177,7 +1176,6 @@ static int dwc3_core_init_mode(struct dwc3 *dwc)
dev_err(dev, "failed to initialize host\n");
return ret;
}
phy_calibrate(dwc->usb2_generic_phy);
break;
case USB_DR_MODE_OTG:
INIT_WORK(&dwc->drd_work, __dwc3_set_mode);