MIPS: lantiq: remove old reset controller implementation

This code is now replaced by a reset controller in drivers/reset/reset-
lantiq-rcu.c. The old code was never used anyway.

Signed-off-by: Hauke Mehrtens <hauke@hauke-m.de>
Cc: martin.blumenstingl@googlemail.com
Cc: john@phrozen.org
Cc: robh@kernel.org
Cc: andy.shevchenko@gmail.com
Cc: p.zabel@pengutronix.de
Cc: kishon@ti.com
Cc: mark.rutland@arm.com
Cc: linux-mips@linux-mips.org
Cc: linux-mtd@lists.infradead.org
Cc: linux-watchdog@vger.kernel.org
Cc: devicetree@vger.kernel.org
Cc: linux-spi@vger.kernel.org
Patchwork: https://patchwork.linux-mips.org/patch/17124/
Signed-off-by: Ralf Baechle <ralf@linux-mips.org>
hifive-unleashed-5.1
Hauke Mehrtens 2017-08-20 00:18:18 +02:00 committed by Ralf Baechle
parent 79797b6fad
commit ba73f0bcce
1 changed files with 0 additions and 68 deletions

View File

@ -194,74 +194,6 @@ int xrx200_gphy_boot(struct device *dev, unsigned int id, dma_addr_t dev_addr)
return 0;
}
/* reset a io domain for u micro seconds */
void ltq_reset_once(unsigned int module, ulong u)
{
ltq_rcu_w32(ltq_rcu_r32(RCU_RST_REQ) | module, RCU_RST_REQ);
udelay(u);
ltq_rcu_w32(ltq_rcu_r32(RCU_RST_REQ) & ~module, RCU_RST_REQ);
}
static int ltq_assert_device(struct reset_controller_dev *rcdev,
unsigned long id)
{
u32 val;
if (id < 8)
return -1;
val = ltq_rcu_r32(RCU_RST_REQ);
val |= BIT(id);
ltq_rcu_w32(val, RCU_RST_REQ);
return 0;
}
static int ltq_deassert_device(struct reset_controller_dev *rcdev,
unsigned long id)
{
u32 val;
if (id < 8)
return -1;
val = ltq_rcu_r32(RCU_RST_REQ);
val &= ~BIT(id);
ltq_rcu_w32(val, RCU_RST_REQ);
return 0;
}
static int ltq_reset_device(struct reset_controller_dev *rcdev,
unsigned long id)
{
ltq_assert_device(rcdev, id);
return ltq_deassert_device(rcdev, id);
}
static const struct reset_control_ops reset_ops = {
.reset = ltq_reset_device,
.assert = ltq_assert_device,
.deassert = ltq_deassert_device,
};
static struct reset_controller_dev reset_dev = {
.ops = &reset_ops,
.owner = THIS_MODULE,
.nr_resets = 32,
.of_reset_n_cells = 1,
};
void ltq_rst_init(void)
{
reset_dev.of_node = of_find_compatible_node(NULL, NULL,
"lantiq,xway-reset");
if (!reset_dev.of_node)
pr_err("Failed to find reset controller node");
else
reset_controller_register(&reset_dev);
}
static void ltq_machine_restart(char *command)
{
u32 val = ltq_rcu_r32(RCU_RST_REQ);