watchdog: da9063: Fix timeout handling during probe

The watchdog can be enabled in previous steps (e.g. the bootloader). Set
the driver default timeout value (8s) if the watchdog is already running
and the HW_RUNNING flag. So the watchdog core framework will ping the
watchdog till the user space activates the watchdog explicit with the
desired timeout value.

Fixes: 5e9c16e376 ("watchdog: Add DA9063 PMIC watchdog driver.")
Signed-off-by: Marco Felsch <m.felsch@pengutronix.de>
Reviewed-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Wim Van Sebroeck <wim@linux-watchdog.org>
hifive-unleashed-5.1
Marco Felsch 2018-05-28 08:45:46 +02:00 committed by Wim Van Sebroeck
parent 44ee54aabf
commit be9e9c2ad5
1 changed files with 21 additions and 0 deletions

View File

@ -45,6 +45,18 @@ static unsigned int da9063_wdt_timeout_to_sel(unsigned int secs)
return DA9063_TWDSCALE_MAX;
}
/*
* Return 0 if watchdog is disabled, else non zero.
*/
static unsigned int da9063_wdt_is_running(struct da9063 *da9063)
{
unsigned int val;
regmap_read(da9063->regmap, DA9063_REG_CONTROL_D, &val);
return val & DA9063_TWDSCALE_MASK;
}
static int da9063_wdt_disable_timer(struct da9063 *da9063)
{
return regmap_update_bits(da9063->regmap, DA9063_REG_CONTROL_D,
@ -206,6 +218,15 @@ static int da9063_wdt_probe(struct platform_device *pdev)
watchdog_set_drvdata(wdd, da9063);
/* Change the timeout to the default value if the watchdog is running */
if (da9063_wdt_is_running(da9063)) {
unsigned int timeout;
timeout = da9063_wdt_timeout_to_sel(DA9063_WDG_TIMEOUT);
_da9063_wdt_set_timeout(da9063, timeout);
set_bit(WDOG_HW_RUNNING, &wdd->status);
}
return devm_watchdog_register_device(&pdev->dev, wdd);
}