From d791a8c60e9cbd1c4fecbc5c86ff59c7ffe137e8 Mon Sep 17 00:00:00 2001 From: "K. Y. Srinivasan" Date: Wed, 27 Jan 2016 18:22:44 -0800 Subject: [PATCH] storvsc: Install the storvsc specific timeout handler for FC devices The default timeout routine used for FC transport is not suitable for FC devices managed by storvsc since FC devices managed by storvsc driver do not have an rport associated with them. Use the time out handler used for SCSI devices for FC devices as well. Signed-off-by: K. Y. Srinivasan Reviewed-by: Alex Ng Tested-by: Vivek Yadav Reviewed-by: Johannes Thumshirn Signed-off-by: Martin K. Petersen --- drivers/scsi/storvsc_drv.c | 6 ++++++ 1 file changed, 6 insertions(+) diff --git a/drivers/scsi/storvsc_drv.c b/drivers/scsi/storvsc_drv.c index 41c115c230d9..622f64a98a9e 100644 --- a/drivers/scsi/storvsc_drv.c +++ b/drivers/scsi/storvsc_drv.c @@ -42,6 +42,7 @@ #include #include #include +#include /* * All wire protocol details (storage protocol between the guest and the host) @@ -1770,6 +1771,11 @@ static int __init storvsc_drv_init(void) fc_transport_template = fc_attach_transport(&fc_transport_functions); if (!fc_transport_template) return -ENODEV; + + /* + * Install Hyper-V specific timeout handler. + */ + fc_transport_template->eh_timed_out = storvsc_eh_timed_out; #endif ret = vmbus_driver_register(&storvsc_drv);