From dd4704480372fdbf3e8f7826274a883c4c7c335a Mon Sep 17 00:00:00 2001 From: Lee Jones Date: Wed, 8 May 2013 14:29:03 +0100 Subject: [PATCH] clk: ux500: Provide device enumeration number suffix for SMSC911x First Ethernet device has a ".0" appended onto the device name. It appears that we need this in order to obtain the correct clock. Without this fix Ethernet does not function on Ux500 devices, which is a regression. Cc: Ulf Hansson Signed-off-by: Lee Jones Signed-off-by: Mike Turquette [mturquette@linaro.org: improved changelog] --- drivers/clk/ux500/u8500_clk.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/clk/ux500/u8500_clk.c b/drivers/clk/ux500/u8500_clk.c index 0b4f35a5ffc2..80069c370a47 100644 --- a/drivers/clk/ux500/u8500_clk.c +++ b/drivers/clk/ux500/u8500_clk.c @@ -325,7 +325,7 @@ void u8500_clk_init(u32 clkrst1_base, u32 clkrst2_base, u32 clkrst3_base, clk = clk_reg_prcc_pclk("p3_pclk0", "per3clk", clkrst3_base, BIT(0), 0); clk_register_clkdev(clk, "fsmc", NULL); - clk_register_clkdev(clk, NULL, "smsc911x"); + clk_register_clkdev(clk, NULL, "smsc911x.0"); clk = clk_reg_prcc_pclk("p3_pclk1", "per3clk", clkrst3_base, BIT(1), 0);