thermal: imx: Use better parameter names than "val"

The values passed to imx_init_calib() and imx_init_temp_grade() are
read from specific OCOTP values. Use their names (in lower case) as
parameter name instead of "val" to make the code easier to understand.

Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
hifive-unleashed-5.1
Uwe Kleine-König 2017-11-30 10:17:35 +01:00 committed by Eduardo Valentin
parent d790405d1b
commit e4bb2240d4
1 changed files with 5 additions and 5 deletions

View File

@ -347,13 +347,13 @@ static struct thermal_zone_device_ops imx_tz_ops = {
.set_trip_temp = imx_set_trip_temp,
};
static int imx_init_calib(struct platform_device *pdev, u32 val)
static int imx_init_calib(struct platform_device *pdev, u32 ocotp_ana1)
{
struct imx_thermal_data *data = platform_get_drvdata(pdev);
int t1, n1;
u64 temp64;
if (val == 0 || val == ~0) {
if (ocotp_ana1 == 0 || ocotp_ana1 == ~0) {
dev_err(&pdev->dev, "invalid sensor calibration data\n");
return -EINVAL;
}
@ -364,7 +364,7 @@ static int imx_init_calib(struct platform_device *pdev, u32 val)
* Use universal formula now and only need sensor value @ 25C
* slope = 0.4297157 - (0.0015976 * 25C fuse)
*/
n1 = val >> 20;
n1 = ocotp_ana1 >> 20;
t1 = 25; /* t1 always 25C */
/*
@ -392,12 +392,12 @@ static int imx_init_calib(struct platform_device *pdev, u32 val)
return 0;
}
static void imx_init_temp_grade(struct platform_device *pdev, u32 val)
static void imx_init_temp_grade(struct platform_device *pdev, u32 ocotp_mem0)
{
struct imx_thermal_data *data = platform_get_drvdata(pdev);
/* The maximum die temp is specified by the Temperature Grade */
switch ((val >> 6) & 0x3) {
switch ((ocotp_mem0 >> 6) & 0x3) {
case 0: /* Commercial (0 to 95C) */
data->temp_grade = "Commercial";
data->temp_max = 95000;