serial: samsung: Fix unintended usage of uart port 0 as console

In s3c24xx_serial_console_setup function, if the uart port that is
being setup as a console has not been initialized, an error can be
returned instead of using uart port 0 as the default console port.
The uart port that was intended to be used as a console could be
initialized at a later point during boot and then registered as a
console. This will avoid using uart port 0 as a unintended console
port.

Signed-off-by: Thomas Abraham <thomas.ab@samsung.com>
Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>
hifive-unleashed-5.1
Thomas Abraham 2011-06-14 19:12:26 +09:00 committed by Kukjin Kim
parent 2c53b436a3
commit ee430f1625
1 changed files with 2 additions and 4 deletions

View File

@ -1416,10 +1416,8 @@ s3c24xx_serial_console_setup(struct console *co, char *options)
/* is the port configured? */
if (port->mapbase == 0x0) {
co->index = 0;
port = &s3c24xx_serial_ports[co->index].port;
}
if (port->mapbase == 0x0)
return -ENODEV;
cons_uart = port;