1
0
Fork 0

power_supply: Add a charge_type property, and use it for olpc driver

This adds a new sysfs file called 'charge_type' which displays the
type of charging (unknown, n/a, trickle charge, or fast charging).

This allows things like battery diagnostics to determine what the
battery/EC is doing without resorting to changing the 'status' sysfs
output.

Signed-off-by: Andres Salomon <dilinger@collabora.co.uk>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
hifive-unleashed-5.1
Andres Salomon 2009-07-02 09:45:18 -04:00 committed by Anton Vorontsov
parent 144bbeaedc
commit ee8076ed3e
4 changed files with 28 additions and 0 deletions

View File

@ -76,6 +76,11 @@ STATUS - this attribute represents operating status (charging, full,
discharging (i.e. powering a load), etc.). This corresponds to
BATTERY_STATUS_* values, as defined in battery.h.
CHARGE_TYPE - batteries can typically charge at different rates.
This defines trickle and fast charges. For batteries that
are already charged or discharging, 'n/a' can be displayed (or
'unknown', if the status is not known).
HEALTH - represents health of the battery, values corresponds to
POWER_SUPPLY_HEALTH_*, defined in battery.h.

View File

@ -233,6 +233,14 @@ static int olpc_bat_get_property(struct power_supply *psy,
if (ret)
return ret;
break;
case POWER_SUPPLY_PROP_CHARGE_TYPE:
if (ec_byte & BAT_STAT_TRICKLE)
val->intval = POWER_SUPPLY_CHARGE_TYPE_TRICKLE;
else if (ec_byte & BAT_STAT_CHARGING)
val->intval = POWER_SUPPLY_CHARGE_TYPE_FAST;
else
val->intval = POWER_SUPPLY_CHARGE_TYPE_NONE;
break;
case POWER_SUPPLY_PROP_PRESENT:
val->intval = !!(ec_byte & (BAT_STAT_PRESENT |
BAT_STAT_TRICKLE));
@ -325,6 +333,7 @@ static int olpc_bat_get_property(struct power_supply *psy,
static enum power_supply_property olpc_bat_props[] = {
POWER_SUPPLY_PROP_STATUS,
POWER_SUPPLY_PROP_CHARGE_TYPE,
POWER_SUPPLY_PROP_PRESENT,
POWER_SUPPLY_PROP_HEALTH,
POWER_SUPPLY_PROP_TECHNOLOGY,

View File

@ -43,6 +43,9 @@ static ssize_t power_supply_show_property(struct device *dev,
static char *status_text[] = {
"Unknown", "Charging", "Discharging", "Not charging", "Full"
};
static char *charge_type[] = {
"Unknown", "N/A", "Trickle", "Fast"
};
static char *health_text[] = {
"Unknown", "Good", "Overheat", "Dead", "Over voltage",
"Unspecified failure", "Cold",
@ -70,6 +73,8 @@ static ssize_t power_supply_show_property(struct device *dev,
if (off == POWER_SUPPLY_PROP_STATUS)
return sprintf(buf, "%s\n", status_text[value.intval]);
else if (off == POWER_SUPPLY_PROP_CHARGE_TYPE)
return sprintf(buf, "%s\n", charge_type[value.intval]);
else if (off == POWER_SUPPLY_PROP_HEALTH)
return sprintf(buf, "%s\n", health_text[value.intval]);
else if (off == POWER_SUPPLY_PROP_TECHNOLOGY)
@ -86,6 +91,7 @@ static ssize_t power_supply_show_property(struct device *dev,
static struct device_attribute power_supply_attrs[] = {
/* Properties of type `int' */
POWER_SUPPLY_ATTR(status),
POWER_SUPPLY_ATTR(charge_type),
POWER_SUPPLY_ATTR(health),
POWER_SUPPLY_ATTR(present),
POWER_SUPPLY_ATTR(online),

View File

@ -38,6 +38,13 @@ enum {
POWER_SUPPLY_STATUS_FULL,
};
enum {
POWER_SUPPLY_CHARGE_TYPE_UNKNOWN = 0,
POWER_SUPPLY_CHARGE_TYPE_NONE,
POWER_SUPPLY_CHARGE_TYPE_TRICKLE,
POWER_SUPPLY_CHARGE_TYPE_FAST,
};
enum {
POWER_SUPPLY_HEALTH_UNKNOWN = 0,
POWER_SUPPLY_HEALTH_GOOD,
@ -70,6 +77,7 @@ enum {
enum power_supply_property {
/* Properties of type `int' */
POWER_SUPPLY_PROP_STATUS = 0,
POWER_SUPPLY_PROP_CHARGE_TYPE,
POWER_SUPPLY_PROP_HEALTH,
POWER_SUPPLY_PROP_PRESENT,
POWER_SUPPLY_PROP_ONLINE,