net: fec: Fix PHY init after phy_reset_after_clk_enable()

[ Upstream commit 0da1ccbbef ]

The phy_reset_after_clk_enable() does a PHY reset, which means the PHY
loses its register settings. The fec_enet_mii_probe() starts the PHY
and does the necessary calls to configure the PHY via PHY framework,
and loads the correct register settings into the PHY. Therefore,
fec_enet_mii_probe() should be called only after the PHY has been
reset, not before as it is now.

Fixes: 1b0a83ac04 ("net: fec: add phy_reset_after_clk_enable() support")
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Tested-by: Richard Leitner <richard.leitner@skidata.com>
Signed-off-by: Marek Vasut <marex@denx.de>
Cc: Christoph Niedermaier <cniedermaier@dh-electronics.com>
Cc: David S. Miller <davem@davemloft.net>
Cc: NXP Linux Team <linux-imx@nxp.com>
Cc: Shawn Guo <shawnguo@kernel.org>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
5.4-rM2-2.2.x-imx-squashed
Marek Vasut 2020-10-06 15:52:53 +02:00 committed by Greg Kroah-Hartman
parent 9e70485b40
commit f08752a449
1 changed files with 5 additions and 5 deletions

View File

@ -3003,17 +3003,17 @@ fec_enet_open(struct net_device *ndev)
/* Init MAC prior to mii bus probe */
fec_restart(ndev);
/* Probe and connect to PHY when open the interface */
ret = fec_enet_mii_probe(ndev);
if (ret)
goto err_enet_mii_probe;
/* Call phy_reset_after_clk_enable() again if it failed during
* phy_reset_after_clk_enable() before because the PHY wasn't probed.
*/
if (reset_again)
fec_enet_phy_reset_after_clk_enable(ndev);
/* Probe and connect to PHY when open the interface */
ret = fec_enet_mii_probe(ndev);
if (ret)
goto err_enet_mii_probe;
if (fep->quirks & FEC_QUIRK_ERR006687)
imx6q_cpuidle_fec_irqs_used();