1
0
Fork 0
Commit Graph

3 Commits (redonkable)

Author SHA1 Message Date
Tobin C. Harding 2880984970 docs: networking: Fix failover build warnings
Currently building the net_failover docs causes a bunch of warnings to
be emitted.  These warnings are all related to indentation and correctly
highlight missing '::' (for code sections).  It looks, from other rst
files in Documentation, that the first column should be indented 2
spaces.

Add '::' before code snippets and indent all snippets uniformly starting
with 2 spaces.

Cc: Jonathan Corbet <corbet@lwn.net>
Signed-off-by: Tobin C. Harding <me@tobin.cc>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-07-16 11:23:54 -07:00
Sridhar Samudrala ba5e4426e8 virtio_net: Extend virtio to use VF datapath when available
This patch enables virtio_net to switch over to a VF datapath when STANDBY
feature is enabled and a VF netdev is present with the same MAC address.
It allows live migration of a VM with a direct attached VF without the need
to setup a bond/team between a VF and virtio net device in the guest.

It uses the API that is exported by the net_failover driver to create and
and destroy a master failover netdev. When STANDBY feature is enabled, an
additional netdev(failover netdev) is created that acts as a master device
and tracks the state of the 2 lower netdevs. The original virtio_net netdev
is marked as 'standby' netdev and a passthru device with the same MAC is
registered as 'primary' netdev.

The hypervisor needs to unplug the VF device from the guest on the source
host and reset the MAC filter of the VF to initiate failover of datapath
to virtio before starting the migration. After the migration is completed,
the destination hypervisor sets the MAC filter on the VF and plugs it back
to the guest to switch over to VF datapath.

This patch is based on the discussion initiated by Jesse on this thread.
https://marc.info/?l=linux-virtualization&m=151189725224231&w=2

Signed-off-by: Sridhar Samudrala <sridhar.samudrala@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-05-28 22:59:54 -04:00
Sridhar Samudrala cfc80d9a11 net: Introduce net_failover driver
The net_failover driver provides an automated failover mechanism via APIs
to create and destroy a failover master netdev and manages a primary and
standby slave netdevs that get registered via the generic failover
infrastructure.

The failover netdev acts a master device and controls 2 slave devices. The
original paravirtual interface gets registered as 'standby' slave netdev and
a passthru/vf device with the same MAC gets registered as 'primary' slave
netdev. Both 'standby' and 'failover' netdevs are associated with the same
'pci' device. The user accesses the network interface via 'failover' netdev.
The 'failover' netdev chooses 'primary' netdev as default for transmits when
it is available with link up and running.

This can be used by paravirtual drivers to enable an alternate low latency
datapath. It also enables hypervisor controlled live migration of a VM with
direct attached VF by failing over to the paravirtual datapath when the VF
is unplugged.

Signed-off-by: Sridhar Samudrala <sridhar.samudrala@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-05-28 22:59:54 -04:00