Hans de Goede 0145b50566 iio/hid-sensors: Fix IIO_CHAN_INFO_RAW returning wrong values for signed numbers
Before this commit sensor_hub_input_attr_get_raw_value() failed to take
the signedness of 16 and 8 bit values into account, returning e.g.
65436 instead of -100 for the z-axis reading of an accelerometer.

This commit adds a new is_signed parameter to the function and makes all
callers pass the appropriate value for this.

While at it, this commit also fixes up some neighboring lines where
statements were needlessly split over 2 lines to improve readability.

Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Acked-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2018-11-16 11:42:12 +00:00
Jonathan Cameron 13a8c6c2a1 iio:humidity: drop assign iio_info.driver_module and iio_trigger_ops.owner
The equivalent of both of these are now done via macro magic when
the relevant register calls are made.  The actual structure
elements will shortly go away.

Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Reviewed-by: Lars-Peter Clausen <lars@metafoo.de>
2017-08-22 21:30:20 +01:00
Song Hongyan d7ed89d5aa iio: hid: Add humidity sensor support
Environmental humidity sensor is a hid defined sensor,
it shows raw humidity measurement of air.

More information can be found in:
http://www.usb.org/developers/hidpage/HUTRR39b.pdf

According to IIO ABI definition, humidityrelative data output unit is
milli percent. Add the unit convert from percent to milli percent.

Signed-off-by: Song Hongyan <hongyan.song@intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2017-03-25 16:32:24 +00:00