1
0
Fork 0
Commit Graph

5 Commits (b7bd05b8d546cebbf05e98194b54d7b122aadf0e)

Author SHA1 Message Date
Anton Vorontsov df58c04c9f charger-manager: Simplify charger_get_property(), get rid of a warning
This patch fixes the following warning and makes the code a little
bit more simpler:

  CC      drivers/power/charger-manager.o
charger-manager.c: In function 'charger_get_property':
charger-manager.c:429:15: warning: 'i' may be used uninitialized in this function [-Wuninitialized]

Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
2012-03-26 20:41:20 +04:00
Axel Lin bb2a95c2d2 charger-manager: Clean up for better readability
This patch includes below changes:

* Some code change for better readability.
* Current code in probe already ensures desc->charger_regulators
  is not NULL. No need to check if it is NULL or not before calling
  regulator_bulk_free().
* Use dev_get_drvdata() in cm_suspend_prepare() and cm_suspend_complete()

Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
2012-03-26 20:41:19 +04:00
Axel Lin 1bbe24d465 power_supply: Fix modalias for charger-manager
Since 43cc71eed1, the platform
modalias is prefixed with "platform:".
Current code has the id_table, thus add MODULE_DEVICE_TABLE will
automatically setup the modalias.

Also make charger_manager_id static as it is only used in this driver.

Signed-off-by: Axel Lin <axel.lin@gmail.com>
Acked-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
2012-02-01 21:29:52 +04:00
Donggeun Kim ad3d13eee7 power_supply: Charger-Manager: Add properties for power-supply-class
Charger Manager provides power-supply-class aggregating
information from multiple chargers and a fuel-gauge.

Signed-off-by: Donggeun Kim <dg77.kim@samsung.com>
Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
2012-01-04 08:08:45 +04:00
Donggeun Kim 3bb3dbbd56 power_supply: Add initial Charger-Manager driver
Because battery health monitoring should be done even when suspended,
it needs to wake up and suspend periodically. Thus, userspace battery
monitoring may incur too much overhead; every device and task is woken
up periodically. Charger Manager uses suspend-again to provide
in-suspend monitoring.

This patch allows to monitor battery health in-suspend state.

Signed-off-by: Donggeun Kim <dg77.kim@samsung.com>
Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
2012-01-04 08:08:27 +04:00