drm/bridge: adv7511: Reset registers on hotplug

[ Upstream commit 5f34175691 ]

The bridge loses its hw state when the cable is unplugged. If we detect
this case in the hpd handler, reset its state.

Reported-by: Rob Clark <robdclark@gmail.com>
Tested-by: Rob Clark <robdclark@gmail.com>
Reviewed-by: Archit Taneja <architt@codeaurora.org>
Signed-off-by: Sean Paul <seanpaul@chromium.org>
Link: https://patchwork.freedesktop.org/patch/msgid/20180703165648.120401-1-seanpaul@chromium.org
Signed-off-by: Sasha Levin <alexander.levin@microsoft.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
pull/10/head
Sean Paul 2018-07-03 12:56:03 -04:00 committed by Greg Kroah-Hartman
parent 7cb625dd9e
commit 384f0d9fe4
1 changed files with 12 additions and 0 deletions

View File

@ -424,6 +424,18 @@ static void adv7511_hpd_work(struct work_struct *work)
else
status = connector_status_disconnected;
/*
* The bridge resets its registers on unplug. So when we get a plug
* event and we're already supposed to be powered, cycle the bridge to
* restore its state.
*/
if (status == connector_status_connected &&
adv7511->connector.status == connector_status_disconnected &&
adv7511->powered) {
regcache_mark_dirty(adv7511->regmap);
adv7511_power_on(adv7511);
}
if (adv7511->connector.status != status) {
adv7511->connector.status = status;
drm_kms_helper_hotplug_event(adv7511->connector.dev);