max77818-charger: update default settings to match hardware reset ones
In case there is no corresponding properties found in device tree, the charger settings should be using values coming out of hardware reset, which are most sensible ones. Signed-off-by: Shawn Guo <shawn.guo@linaro.org>pull/10/head
parent
8ac34b3f4d
commit
7417accbec
|
@ -804,22 +804,22 @@ static int max77818_charger_parse_dt(struct max77818_charger *chg)
|
|||
|
||||
if (of_property_read_u32(np, "fast_charge_timer",
|
||||
&chg->fast_charge_timer))
|
||||
chg->fast_charge_timer = 0; // disable
|
||||
chg->fast_charge_timer = 4; // 4 hours
|
||||
|
||||
if (of_property_read_u32(np, "fast_charge_current",
|
||||
&chg->fast_charge_current))
|
||||
chg->fast_charge_current = 500; // 500mA
|
||||
chg->fast_charge_current = 450; // 450mA
|
||||
|
||||
if (of_property_read_u32(np, "charge_termination_voltage",
|
||||
&chg->termination_voltage))
|
||||
chg->termination_voltage = 4350; // 4350mV
|
||||
chg->termination_voltage = 4200; // 4200mV
|
||||
|
||||
if (of_property_read_u32(np, "topoff_timer", &chg->topoff_timer))
|
||||
chg->topoff_timer = 30; // 30 min
|
||||
|
||||
if (of_property_read_u32(np, "topoff_current",
|
||||
&chg->topoff_current))
|
||||
chg->topoff_current = 200; // 200mA
|
||||
chg->topoff_current = 150; // 150mA
|
||||
|
||||
if (of_property_read_u32(np, "restart_threshold",
|
||||
&chg->restart_threshold))
|
||||
|
|