1
0
Fork 0

firewire: sbp2: Take into account Unit_Unique_ID

If the target's unit directory contains a Unit_Unique_ID entry, we
should use that as the target's GUID for identification purposes. The
SBP-2 standards document says:

"Although the node unique ID (EUI-64) present in the bus information
block is sufficient to uniquely identify nodes attached to Serial Bus,
it is insufficient to identify a target when a vendor implements a
device with multiple Serial Bus node connections. In this case initiator
software requires information by which a particular target may be
uniquely identified, regardless of the Serial Bus access path used."

[ IEEE T10 P1155D Revision 4, Section 7.6 (page 51) ] and
[ IEEE T10 P1467D Revision 5, Section 7.9 (page 74) ]

Signed-off-by: Chris Boot <bootc@bootc.net>
Signed-off-by: Stefan Richter <stefanr@s5r6.in-berlin.de>
wifi-calibration
Chris Boot 2012-02-15 14:59:08 +00:00 committed by Stefan Richter
parent e894d1d7fd
commit 8ff6a75744
1 changed files with 12 additions and 0 deletions

View File

@ -218,6 +218,7 @@ static const struct device *lu_dev(const struct sbp2_logical_unit *lu)
#define SBP2_CSR_UNIT_CHARACTERISTICS 0x3a
#define SBP2_CSR_FIRMWARE_REVISION 0x3c
#define SBP2_CSR_LOGICAL_UNIT_NUMBER 0x14
#define SBP2_CSR_UNIT_UNIQUE_ID 0x8d
#define SBP2_CSR_LOGICAL_UNIT_DIRECTORY 0xd4
/* Management orb opcodes */
@ -1005,6 +1006,13 @@ static int sbp2_add_logical_unit(struct sbp2_target *tgt, int lun_entry)
return 0;
}
static void sbp2_get_unit_unique_id(struct sbp2_target *tgt,
const u32 *leaf)
{
if ((leaf[0] & 0xffff0000) == 0x00020000)
tgt->guid = (u64)leaf[1] << 32 | leaf[2];
}
static int sbp2_scan_logical_unit_dir(struct sbp2_target *tgt,
const u32 *directory)
{
@ -1056,6 +1064,10 @@ static int sbp2_scan_unit_dir(struct sbp2_target *tgt, const u32 *directory,
return -ENOMEM;
break;
case SBP2_CSR_UNIT_UNIQUE_ID:
sbp2_get_unit_unique_id(tgt, ci.p - 1 + value);
break;
case SBP2_CSR_LOGICAL_UNIT_DIRECTORY:
/* Adjust for the increment in the iterator */
if (sbp2_scan_logical_unit_dir(tgt, ci.p - 1 + value) < 0)