Revert "microblaze_mmu_v2: Update signal returning address"

This reverts commit 8b28626a6b.

Offset -8 is wrong because when it is applied then one instruction
before brki r14, 8 is called again when we return.
Offset -4 is correct and brki instruction is called again.

This change came from ancient MMU kernel.

Signed-off-by: Michal Simek <monstr@monstr.eu>
This commit is contained in:
Michal Simek 2011-05-23 11:38:19 +02:00
parent c74c8b1dcb
commit 94fda49a94

View file

@ -290,15 +290,7 @@ handle_restart(struct pt_regs *regs, struct k_sigaction *ka, int has_handler)
case -ERESTARTNOINTR:
do_restart:
/* offset of 4 bytes to re-execute trap (brki) instruction */
#ifndef CONFIG_MMU
regs->pc -= 4;
#else
/* offset of 8 bytes required = 4 for rtbd
offset, plus 4 for size of
"brki r14,8"
instruction. */
regs->pc -= 8;
#endif
break;
}
}