iio: pressure: bmp280: fix relative humidity unit
[ Upstream commitpull/10/head13399ff25f
] According to IIO ABI relative humidity reading should be returned in milli percent. This patch addresses that by applying proper scaling and returning integer instead of fractional format type specifier. Note that the fixes tag is before the driver was heavily refactored to introduce spi support, so the patch won't apply that far back. Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com> Fixes:14beaa8f5a
("iio: pressure: bmp280: add humidity support") Acked-by: Matt Ranostay <matt.ranostay@konsulko.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Signed-off-by: Sasha Levin <alexander.levin@microsoft.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
parent
9265a45095
commit
dc68381f49
|
@ -362,10 +362,9 @@ static int bmp280_read_humid(struct bmp280_data *data, int *val, int *val2)
|
|||
}
|
||||
comp_humidity = bmp280_compensate_humidity(data, adc_humidity);
|
||||
|
||||
*val = comp_humidity;
|
||||
*val2 = 1024;
|
||||
*val = comp_humidity * 1000 / 1024;
|
||||
|
||||
return IIO_VAL_FRACTIONAL;
|
||||
return IIO_VAL_INT;
|
||||
}
|
||||
|
||||
static int bmp280_read_raw(struct iio_dev *indio_dev,
|
||||
|
|
Loading…