Fix serial console on SNI RM400 machines

sccnxp driver doesn't get the correct uart clock rate, if CONFIG_HAVE_CLOCK
is disabled. Correct usage of clk API to make it work with/without it.

Fixes: 90efa75f7a (serial: sccnxp: Using CLK API for getting UART clock)

Suggested-by: Russell King - ARM Linux <linux@armlinux.org.uk>
Signed-off-by: Thomas Bogendoerfer <tsbogend@alpha.franken.de>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
zero-colors
Thomas Bogendoerfer 2017-05-31 22:21:03 +02:00 committed by Greg Kroah-Hartman
parent 8a8dabf2dd
commit e279e6d98e
1 changed files with 10 additions and 5 deletions

View File

@ -884,14 +884,19 @@ static int sccnxp_probe(struct platform_device *pdev)
clk = devm_clk_get(&pdev->dev, NULL);
if (IS_ERR(clk)) {
if (PTR_ERR(clk) == -EPROBE_DEFER) {
ret = -EPROBE_DEFER;
ret = PTR_ERR(clk);
if (ret == -EPROBE_DEFER)
goto err_out;
}
uartclk = 0;
} else {
clk_prepare_enable(clk);
uartclk = clk_get_rate(clk);
}
if (!uartclk) {
dev_notice(&pdev->dev, "Using default clock frequency\n");
uartclk = s->chip->freq_std;
} else
uartclk = clk_get_rate(clk);
}
/* Check input frequency */
if ((uartclk < s->chip->freq_min) || (uartclk > s->chip->freq_max)) {