1
0
Fork 0

fdt: fix address cell count checking in fdt_translate_address()

Commit: dm: core: Enable optional use of fdt_translate_address()

Enables use of this function as default, but after this it's not
possible to get dev address for the case in which: '#size-cells == 0'

This causes errors when getting address for some GPIOs, for which
the '#size-cells' is set to 0.

Example error:
'__of_translate_address: Bad cell count for gpx0'

Allowing for that case by modifying the macro 'OF_CHECK_COUNTS',
(called from )__of_translate_address(), fixes the issue.

Now, this macro doesn't check, that '#size-cells' is greater than 0.

This is possible from the specification point of view, but I'm not sure
that it doesn't introduce a regression for other configs.

Please test and share the results.

Tested-on: Odroid U3, Odroid X2, Odroid XU3, Sandbox.

Signed-off-by: Przemyslaw Marczak <p.marczak@samsung.com>
Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
Cc: Lukasz Majewski <l.majewski@samsung.com>
Cc: Jaehoon Chung <jh80.chung@samsung.com>
Cc: Stefan Roese <sr@denx.de>
Cc: Simon Glass <sjg@chromium.org>
Cc: Bin Meng <bmeng.cn@gmail.com>
Cc: Marek Vasut <marex@denx.de>
Tested-by: Jaehoon Chung <jh80.chung@samsung.com>
Tested-by: Lukasz Majewski <l.majewski@samsung.com>
utp
Przemyslaw Marczak 2015-10-28 15:37:57 +01:00 committed by Simon Glass
parent 8a83487030
commit 71105f50fe
1 changed files with 3 additions and 4 deletions

View File

@ -952,8 +952,7 @@ void fdt_del_node_and_alias(void *blob, const char *alias)
/* Max address size we deal with */
#define OF_MAX_ADDR_CELLS 4
#define OF_BAD_ADDR FDT_ADDR_T_NONE
#define OF_CHECK_COUNTS(na, ns) ((na) > 0 && (na) <= OF_MAX_ADDR_CELLS && \
(ns) > 0)
#define OF_CHECK_COUNTS(na) ((na) > 0 && (na) <= OF_MAX_ADDR_CELLS)
/* Debug utility */
#ifdef DEBUG
@ -1121,7 +1120,7 @@ static u64 __of_translate_address(void *blob, int node_offset, const fdt32_t *in
/* Cound address cells & copy address locally */
bus->count_cells(blob, parent, &na, &ns);
if (!OF_CHECK_COUNTS(na, ns)) {
if (!OF_CHECK_COUNTS(na)) {
printf("%s: Bad cell count for %s\n", __FUNCTION__,
fdt_get_name(blob, node_offset, NULL));
goto bail;
@ -1148,7 +1147,7 @@ static u64 __of_translate_address(void *blob, int node_offset, const fdt32_t *in
/* Get new parent bus and counts */
pbus = &of_busses[0];
pbus->count_cells(blob, parent, &pna, &pns);
if (!OF_CHECK_COUNTS(pna, pns)) {
if (!OF_CHECK_COUNTS(pna)) {
printf("%s: Bad cell count for %s\n", __FUNCTION__,
fdt_get_name(blob, node_offset, NULL));
break;