clk: imx: clk-pllv3: fix incorrect handle of enet powerdown bit

After commit f53947456f ("ARM: clk: imx: update pllv3 to support imx7"),
the former used BM_PLL_POWER bit is not correct anymore for IMX7 ENET.
Instead, pll->powerdown holds the correct bit, so using powerdown bit
in clk_pllv3_{prepare | unprepare} functions.

Fixes: f53947456f ("ARM: clk: imx: update pllv3 to support imx7")
Signed-off-by: Dong Aisheng <aisheng.dong@nxp.com>
Signed-off-by: Shawn Guo <shawnguo@kernel.org>
This commit is contained in:
Dong Aisheng 2016-06-08 22:33:30 +08:00 committed by Shawn Guo
parent f83d31635c
commit b3e76bdc0b

View file

@ -77,9 +77,9 @@ static int clk_pllv3_prepare(struct clk_hw *hw)
val = readl_relaxed(pll->base);
if (pll->powerup_set)
val |= BM_PLL_POWER;
val |= pll->powerdown;
else
val &= ~BM_PLL_POWER;
val &= ~pll->powerdown;
writel_relaxed(val, pll->base);
return clk_pllv3_wait_lock(pll);
@ -92,9 +92,9 @@ static void clk_pllv3_unprepare(struct clk_hw *hw)
val = readl_relaxed(pll->base);
if (pll->powerup_set)
val &= ~BM_PLL_POWER;
val &= ~pll->powerdown;
else
val |= BM_PLL_POWER;
val |= pll->powerdown;
writel_relaxed(val, pll->base);
}