soldlow/kicad/soldlow.ses

286 lines
6.2 KiB
Plaintext

(session soldlow.ses
(base_design soldlow.dsn)
(placement
(resolution um 10)
(component "Package_DIP:SMDIP-8_W9.53mm"
(place U1 6985000 -1955800 front 270)
)
(component "Diode_THT:D_DO-247_Vertical"
(place D1 7137400 -1981200 front 0)
)
(component Resistor_THT:R_Axial_DIN0207_L6.3mm_D2.5mm_P10.16mm_Horizontal
(place R1 6858000 -2311400 front 0)
)
(component Resistor_THT:R_Axial_DIN0207_L6.3mm_D2.5mm_P10.16mm_Horizontal::1
(place R4 6959600 -2209800 front 180)
)
(component Resistor_THT:R_Axial_DIN0207_L6.3mm_D2.5mm_P10.16mm_Horizontal::2
(place R2 7035800 -2260600 front 0)
)
(component Resistor_THT:R_Axial_DIN0207_L6.3mm_D2.5mm_P10.16mm_Horizontal::3
(place R3 6883400 -1803400 front 180)
)
(component Resistor_THT:R_Axial_DIN0207_L6.3mm_D2.5mm_P10.16mm_Horizontal::4
(place R6 7010400 -1803400 front 0)
)
(component Resistor_THT:R_Axial_DIN0207_L6.3mm_D2.5mm_P10.16mm_Horizontal::5
(place R5 6781800 -2082800 front 90)
)
(component Capacitor_THT:CP_Radial_D5.0mm_P2.50mm
(place C2 7162800 -2108200 front 0)
)
(component Capacitor_THT:CP_Radial_D5.0mm_P2.50mm::1
(place C1 6984600 -1701800 front 180)
)
)
(was_is
)
(routes
(resolution um 10)
(parser
(host_cad "KiCad's Pcbnew")
(host_version "6.0.0-1")
)
(library_out
(padstack "Via[0-1]_800:400_um"
(shape
(circle F.Cu 8000 0 0)
)
(shape
(circle B.Cu 8000 0 0)
)
(attach off)
)
)
(network_out
(net "Net-(D1-Pad2)"
(wire
(path F.Cu 2500
6933650 -2016750
6933650 -1946800
6960140 -1920310
6960140 -1908150
)
)
(wire
(path F.Cu 2500
6781800 -2082800
6867600 -2082800
6933650 -2016750
)
)
(wire
(path F.Cu 2500
6933650 -2016750
6958350 -2016750
6959070 -2016030
6959070 -1991830
6960720 -1990180
7076170 -1990180
7092960 -2006970
7204870 -2006970
7230640 -1981200
)
)
(wire
(path F.Cu 2500
7246400 -1981200
7230640 -1981200
)
)
(wire
(path F.Cu 2500
6972300 -1908150
6960140 -1908150
)
)
)
(net GNDPWR
(wire
(path B.Cu 2500
6781800 -1981200
6781800 -1992460
)
)
(wire
(path B.Cu 2500
6781800 -1992460
6858000 -2068660
6858000 -2209800
)
)
(wire
(path B.Cu 2500
6781800 -1981200
6781800 -1803400
)
)
)
(net "Net-(U1-Pad1)"
(wire
(path F.Cu 2500
7023100 -1908150
7023100 -1894890
)
)
(wire
(path F.Cu 2500
7112000 -1803400
7112000 -1814660
)
)
(wire
(path F.Cu 2500
7112000 -1814660
7031770 -1894890
7023100 -1894890
)
)
(wire
(path F.Cu 2500
7023100 -1908150
7023100 -1921410
)
)
(wire
(path F.Cu 2500
6946900 -2003450
6946900 -1990190
)
)
(wire
(path F.Cu 2500
7023100 -1921410
6954320 -1990190
6946900 -1990190
)
)
(wire
(path B.Cu 2500
6984600 -1701800
6995860 -1701800
)
)
(wire
(path B.Cu 2500
6995860 -1701800
7097460 -1803400
7112000 -1803400
)
)
)
(net "Net-(R3-Pad1)"
(wire
(path F.Cu 2500
7010400 -1803400
6997700 -1816100
6997700 -1908150
)
)
(wire
(path B.Cu 2500
6959600 -1752600
7010400 -1803400
)
)
(wire
(path B.Cu 2500
6959600 -1701800
6959600 -1752600
)
)
(wire
(path B.Cu 2500
6959600 -1752600
6934200 -1752600
6883400 -1803400
)
)
)
(net "Net-(R4-Pad1)"
(wire
(path F.Cu 2500
7025555 -2256705
6970860 -2311400
)
)
(wire
(path F.Cu 2500
7035800 -2260600
7031900 -2256700
7025560 -2256700
7025555 -2256705
)
)
(wire
(path F.Cu 2500
6972300 -2203450
7025555 -2256705
)
)
(wire
(path F.Cu 2500
6959600 -2311400
6970860 -2311400
)
)
(wire
(path F.Cu 2500
6959600 -2209800
6965950 -2203450
6972300 -2203450
)
)
(wire
(path F.Cu 2500
6972300 -2203450
6972300 -2108200
)
)
(wire
(path F.Cu 2500
6972300 -2108200
6972300 -2003450
)
)
(wire
(path F.Cu 2500
7162800 -2108200
6972300 -2108200
)
)
)
(net "Net-(U1-Pad7)"
(wire
(path F.Cu 2500
6997700 -2003450
7009860 -2003450
)
)
(wire
(path F.Cu 2500
7187800 -2108200
7104720 -2025120
7019370 -2025120
7009860 -2015610
7009860 -2003450
)
)
(wire
(path B.Cu 2500
7137400 -2260600
7137400 -2249340
)
)
(wire
(path B.Cu 2500
7187800 -2108200
7187800 -2198940
7137400 -2249340
)
)
)
)
)
)